BLACOH FLUID CONTROL - Sentry Sentinel Spill-Stop

Application Stories - Waste Treatment

APPLICATION:
A leading paper manufacture located in Japan uses Air-Operated Double Diaphragm (AODD) pumps to inject process chemicals into a mixing tank.

PROBLEM:
The low viscosity of the liquid, less than 10 centipoises makes the chemical in this particular application very susceptible to the reciprocating action of the pumps. This makes it extremely difficult to maintain any type of accuracy when introducing the chemical into the batch. As a result the quality and consistency of the final product suffers.

SOLUTION:
The installation of a Blacoh inlet stabilizer at the pump’s inlet and a Blacoh pulsation dampener at the pump’s discharge create an even flow into the pump and a pulse free pump discharge which creates a smooth, consistent, laminar flow of the process chemicals. This allows the system instrumentation to function correctly, increasing accuracy and producing a quality product.

RESULT:
Since the Blacoh SENTRY Inlet stabilizers and Pulsation Dampeners have been installed; the surge in the system has been eliminated. The system produces a smooth even discharge, which allows the system to function properly saving the company thousands of dollars in production-associated costs.

SUBMITTED BY:
Mike Chew
Japan Machinery

 

Back to Application Stories

 


©2004 Blacoh Fluid Control, Inc. All Rights Reserved. • E-mail us with your questions or comments.
Blacoh, Pulsation Dampeners, Diaphragm Seals, Leak Containment