BLACOH FLUID CONTROL - Sentry Sentinel Spill-Stop
s

Application Stories - Tank Truck Filling / Hose Abrasion
APPLICATION:
Blacoh Fluid Control recently was contacted by a large manufacturer of bulk chemicals. They use air operated diaphragm pumps (AODD) to load chemicals into tanker trucks through a 20’ flexible/ 3" reinforced hose that lies on a concrete floor.

PROBLEM:
The pulsation generated by their AODD pumps caused the hose to shake back and forth, scuffing the hose on the concrete floor, and causing "hose abrasion". Ultimately, these hoses would fail from abrasion due to the scuffing action. This failure meant considerable downtime, lost product, extensive clean-up, and hose replacement – all of which came with an associated cost.

SOLUTION:
Blacoh Fluid Control installed a SENTRY 5 gallon Pulsation Dampener at the discharge of each of the 3" AODD pumps. The dampener absorbed the pulses generated by the pump and the flow from the pump is now smooth and steady

RESULT:
The hose no longer shakes and scuffs on the concrete floor. Since the installation of the Blacoh Pulsation Dampeners, not a single hose has been replaced due to abrasion failure. The investment in pulsation dampeners has paid for itself several times, in both time and cost savings.

SUBMITTED BY:
Kenneth R. Mink
LIQUID HANDLING EQUIPMENT

 

Back to Application Stories

 


©2004 Blacoh Fluid Control, Inc. All Rights Reserved. • E-mail us with your questions or comments.
Blacoh, Pulsation Dampeners, Diaphragm Seals, Leak Containment